Alarm
Represents NetXMS alarm.
Instance attributes
- ackBy: int
-
ID of user who acknowledged this alarm, or
-1if the alarm was not acknowledged.
- ackByUser ⇒ UserDBObject
-
User who acknowledged this alarm (class User or UserGroup, both derived from UserDBObject), or
nullif the alarm was not acknowledged or the user does not exist.
- categories: Array
-
Array with alarm category names.
- creationTime: int
-
Unix timestamp of the alarm creation time.
- dciId: int
-
If alarm was created as a result of DCI threshold violation, this attribute will contain ID of the DCI.
- eventCode: int
-
Event code of originating event.
- eventId: int
-
ID of originating event.
- eventName: String
-
Name of originating event. If the event template no longer exists, contains the event code.
- eventTagList: String
-
List of event tags as a comma separated string
- helpdeskReference: String
-
Helpdesk system reference (e.g. issue ID).
- helpdeskState: int
-
Helpdesk state:
-
0 = Ignored
-
1 = Open
-
2 = Closed
-
- id: int
-
Unique identifier of the alarm.
- impact: String
-
Alarm impact text
- key: String
-
Alarm key.
- lastChangeTime: int
-
Unix timestamp of the last update.
- message: String
-
Alarm message.
- originalSeverity: int
-
Original severity of the alarm.
- parentId: int
-
Parent alarm id
- repeatCount: int
-
Repeat count.
- resolvedBy: int
-
ID of user who resolved this alarm, or
-1if the alarm was not resolved.
- resolvedByUser ⇒ UserDBObject
-
User who resolved this alarm (class User or UserGroup), or
nullif the alarm was not resolved or the user does not exist.
- rcaScriptName: String
-
Name of root cause analysis script
- ruleGuid: String
-
GUID of the event processing policy rule that created the alarm.
- ruleDescription: String
-
Description of the event processing policy rule that created the alarm.
- severity: int
-
Current alarm severity.
- sourceObject: int
-
ID of the object where alarm is raised.
- state: int
-
Alarm state (see alarm state values):
-
0 = Outstanding
-
1 = Acknowledged
-
2 = Resolved
-
3 = Terminated
-
17 = Sticky acknowledged
-
Instance methods
- acknowledge(includeSubordinates): bool
-
Acknowledge alarm.
Table 1. Parameters includeSubordinates
Boolean
Optional. If
true, subordinate alarms of this alarm are acknowledged as well.falseby default.Returntrueon success,falseon failure.
- addComment(commentText, syncWithHelpdesk): int
-
Add new alarm comment.
Table 2. Parameters commentText
String
Text of the new alarm comment.
syncWithHelpdesk
Boolean
Optional. If
true, the comment is also sent to the linked helpdesk issue.trueby default.ReturnId of the newly created alarm comment, or
nullon failure.
- closeHelpdeskIssue(): bool
-
Mark helpdesk issue linked to this alarm as closed. Helpdesk reference is kept, helpdesk state changes to Closed. Alarm must be in helpdesk state Open.
Returntrueon success,falseif helpdesk state is not Open or the alarm no longer exists.
- getComments(): Array
-
Get array of alarm comments.
ReturnArray of AlarmComment objects.
- requestAiAssistantComment(): String
-
Request an AI assistant comment for this alarm.
ReturnString containing the AI assistant’s response, or
nullif the source object no longer exists or the AI assistant returned no response. The response is not added to the alarm as a comment.
- resolve(includeSubordinates): bool
-
Resolve alarm.
Table 3. Parameters includeSubordinates
Boolean
Optional. If
true, subordinate alarms of this alarm are resolved as well.falseby default.Returntrueon success,falseon failure.
- setHelpdeskReference(reference): bool
-
Link this alarm to an external helpdesk issue without going through the helpdesk integration module. Sets helpdesk reference and changes helpdesk state to Open. Alarm must be in helpdesk state Ignored (not yet linked).
Table 4. Parameters reference
String
Helpdesk system reference (e.g. issue ID). Must not be empty.
Returntrueon success,falseif the alarm is already linked to a helpdesk issue, reference is empty, or the alarm no longer exists.alarm = FindAlarmByKey("DISK_FULL_" .. $node.id); if (alarm != null && alarm.helpdeskState == 0) { if (!alarm.setHelpdeskReference("TICKET-4711")) trace(2, "Cannot set helpdesk reference for alarm " .. alarm.id); }
- terminate(includeSubordinates): bool
-
Terminate alarm.
Table 5. Parameters includeSubordinates
Boolean
Optional. If
true, subordinate alarms of this alarm are terminated as well.falseby default.Returntrueon success,falseon failure.
- unlinkFromHelpdesk(): bool
-
Remove helpdesk link from this alarm. Clears helpdesk reference and resets helpdesk state to Ignored. Works in any helpdesk state.
Returntrueon success,falseif the alarm no longer exists.
FindAlarmByKey, FindAlarmByKeyRegex, FindAlarmById, AlarmComment, Event